: Water Intake Test. Fills the machine up to maximum overflow levels to test pressure switches.
Press and hold the (usually "Spin" or the button directly below the display).
Once in P01 (service mode), you can cycle through different tests by turning the selector dial. Displays the last error code (e.g., E:67 or F:21 ). P02: Software version display. P03: Motor Test: Turns the drum to test motor function. P04: Water Inlet Valve Test: Fills the tub. P05: Heater Test: Activates the heating element. P08: Drain Pump Test: Activates the pump to drain. How to Clear Errors and Reset the Machine bosch serie 6 service mode
: Turn the program selector knob to the 0 or OFF position and wait 2 seconds.
Do NOT run the drying heater test (T:01) with wet laundry inside. You can cause steam burns or damage the moisture sensors. : Water Intake Test
Once inside, you can turn the dial to different positions to run specific tests: Error memory (shows the last faults). P03: Spin test (runs the motor without the balance sensor).
Turn the dial one more click to the clockwise . Once in P01 (service mode), you can cycle
The method to enter the diagnostic menu varies by appliance type and specific model number. Below are common methods for different Bosch Serie 6 appliances.